Product Image
Product added to your wishlist! View wishlist
Sign in to see your saved products on any device
Product removed from your wishlist! View wishlist
Sign in to see your saved products on any device
Something went wrong. Please try again later.
Product is added to compare already. Please refresh the page.
Product is not found in compare. Please refresh the page.
5 Products already added. Please delete existing selection to add this.

Share this product

Iota DLS-30/IQ4, 12 volt 30 amp regulated battery charger/supply with Charge Controller
This product ad may change over time
Share ProductShare

Iota DLS-30/IQ4, 12 volt 30 amp regulated battery charger/supply with Charge Controller

IOTA DLS-30 (30amp 12v Charger) with IQ4 Smart Charge Controller The DLS series converter/power supply output is so clean and ripple-free, it can be used with or without a battery. The DLS series converter/charger quickly and efficiently charges batteries from the full rated output of the DLS. The DLS then maintains the batteries, onl…
IOTA DLS-30 (30amp 12v Charger) with IQ4 Smart Charge Controller The DLS series converter/power supply output is so clean and ripple-free, it can be used with or without a battery. The DLS series converter/charger quickly and efficiently charges batteries from the full rated output of the DLS. The DLS then maintains the batteries, only putting into the battery what is required by load or self discharge, cutting back to milliamps as the battery requires. Low and transient AC line voltage can be a major cause of converter/power supply failure. The DLS series converter/power supply is protected against low line voltage, as well as spikes coming from the AC power source or from improperly adjusted generators. When used as a power supply, the DLS model will only supply what is required by the load. When not in use it is essentially off, reducing electricity usage. External fuses can be quickly and easily replaced. Chargers have 120 VAC input. 75-amp and larger chargers have 120V 20-amp plugs. 2-year warranty. SPECIFICATIONS DC Output Voltage (No Load) approx. 13.6V (DC) Output Voltage Tolerance (No Load) + or - .7% Output Amperage, Max Continuous 30 Amps Output Voltage (Full Load) approx. >13.4V (DC) Maximum Power Output, Continuous 400 Watts Ripple and Noise <50 mV rms Input Voltage Range 108-132V (AC) Input Voltage Frequency 47-63 Maximum AC Current @ 108VAC 7 Amps Typical Efficiency >80% Max Inrush Current, Single Cycle 27 Amps Short Circuit Protection Yes Overload Protection >100% Line Regulation 100 mV rms Load Regulation <1% Fan Control Proportional Thermal Protection YES Working Temperature Range 0-40C Storage Temperature -20 to 80C Withstand Voltage 1240V @ leads Dimensions 9.7" x 6.7" x 3.4" Weight 5.0 lbs The IQ4 Smart Charge Controller The IQ4 Smart Charge Controller offers automatic charging control for DLS battery chargers, providing longer and safer use of your systems battery. The IQ4 controller allows the battery charger to operate as an automatic "smart charger." This gives the user the benefit of Bulk, Absorption, and Float stage charging, decreases charge times, insures proper and safe battery charging, and minimizes overcharging. The IQ4 monitors the battery at all times. If the DLS voltage remains in the long term Float stage for more than seven days, the IQ4 Smart Charger will automatically deliver a boost charge for a predetermined time, then return to the normal Float stage.
See more below
T
The Solar Store
$197.35
Visit site

Description

IOTA DLS-30 (30amp 12v Charger) with IQ4 Smart Charge Controller The DLS series converter/power supply output is so clean and ripple-free, it can be used with or without a battery. The DLS series converter/charger quickly and efficiently charges batteries from the full rated output of the DLS. The DLS then maintains the batteries, only putting into the battery what is required by load or self discharge, cutting back to milliamps as the battery requires. Low and transient AC line voltage can be a major cause of converter/power supply failure. The DLS series converter/power supply is protected against low line voltage, as well as spikes coming from the AC power source or from improperly adjusted generators. When used as a power supply, the DLS model will only supply what is required by the load. When not in use it is essentially off, reducing electricity usage. External fuses can be quickly and easily replaced. Chargers have 120 VAC input. 75-amp and larger chargers have 120V 20-amp plugs. 2-year warranty. SPECIFICATIONS DC Output Voltage (No Load) approx. 13.6V (DC) Output Voltage Tolerance (No Load) + or - .7% Output Amperage, Max Continuous 30 Amps Output Voltage (Full Load) approx. >13.4V (DC) Maximum Power Output, Continuous 400 Watts Ripple and Noise <50 mV rms Input Voltage Range 108-132V (AC) Input Voltage Frequency 47-63 Maximum AC Current @ 108VAC 7 Amps Typical Efficiency >80% Max Inrush Current, Single Cycle 27 Amps Short Circuit Protection Yes Overload Protection >100% Line Regulation 100 mV rms Load Regulation <1% Fan Control Proportional Thermal Protection YES Working Temperature Range 0-40C Storage Temperature -20 to 80C Withstand Voltage 1240V @ leads Dimensions 9.7" x 6.7" x 3.4" Weight 5.0 lbs The IQ4 Smart Charge Controller The IQ4 Smart Charge Controller offers automatic charging control for DLS battery chargers, providing longer and safer use of your systems battery. The IQ4 controller allows the battery charger to operate as an automatic "smart charger." This gives the user the benefit of Bulk, Absorption, and Float stage charging, decreases charge times, insures proper and safe battery charging, and minimizes overcharging. The IQ4 monitors the battery at all times. If the DLS voltage remains in the long term Float stage for more than seven days, the IQ4 Smart Charger will automatically deliver a boost charge for a predetermined time, then return to the normal Float stage.